Skytron · Model SkyVac Smoke Evacuation System
Normal or Turbo Speed Suction provides up to 32 cfm at surgical site “Front-End” Filtration, Low Maintenance Design Optional Automatic Surgeon ON/OFF Control with Auto Sensor Front load filter change is a speedy, one-step process without tools or help from biomed SkyVac universally accepts a wide range of laparoscopic smoke evacuator tubing sets, including 1/4” (6mm), 3/8” (10mm), 7/8” (22mm), 1” (25.4mm) and 1-1/4” (32mm) sizes.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Plume not captured, weak airflow, blower ramps but flow is low.
Root cause: Loaded ULPA / charcoal filter, a worn blower / turbine, or a leak / kink in the hose.
Symptoms: Filter-change alarm, reduced airflow, odour breakthrough.
Root cause: ULPA / activated-charcoal filter at end of its capacity.
Symptoms: Evacuator does not start with the ESU, or runs continuously.
Root cause: The ESU-sensing cuff / cable or the auto-activation board.
Symptoms: Noisy, weak, or dead blower even with a new filter.
Root cause: Worn blower / turbine bearings or motor.
Symptoms: Very loud in use, speed will not adjust.
Root cause: Worn blower or a speed-control fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| ULPA / activated-charcoal filter | Consumable | $$ | Easy |
| Blower / turbine assembly | Periodic replacement | $$$ | Difficult |
| ESU-sensing cuff / auto-activation board | Major service part | $$ | Moderate |
| Hose / wand adapters | Frequent wear item | $ | Easy |
| Speed-control board | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.