Skytron · Model NT2525
• Fixed Focus with Automatic Reserve Bulb • Wall mounted Intensity Control with Reserve Bulb Indicator Light • 25" and 25" Lightheads • Intensity up to 22,000 footcandles (240,000 lux) • Cool Beam Temperature • Glare Reducing, Soft White Light • Optional, Portable High Resolution Sony TV-II Handle Camera System • 360 degree movement at all points of rotation • 90 degree downward travel for low angle lighting requirements, 20 degree upward travel for taller surgeons • Bulb life is 1,000 hours, protected by Skytron's Sof-start system • Applications: General, Trauma, Ortho, Neuro, Ophthalmic, Plastics, Outpatient, Urology, Special Procedures, Delivery, Emergency
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →