SFSchott-Fostec · Model A20800 DCR III
DC-regulated light source limits light fluctuation to ± 0.5% due to line voltage variation Universal input voltage – accepts 90 to 265 VAC Current limiting – protects the unit from over heating due to defective and aging bulbs. Transient protection – allows remote location of bulb. Lamp change indicator light - LED located on front panel changes from green to red when lamp requires replacement. Soft start “lamp saver” circuitry IR filter for cool illumination Solid state dimmer control for continuous dimming Interchangeable Modulamp Units offer 2 lamp positions to maximize individual lamp efficiencies. Choice of three, 150 watt halogen lamps - EKE, EJA and DDL Can power the RS232 from the 9-pin connector Built-in 9-pin connector for analog remote control or RS-232 connection (A20601) Detachable IEC cord Quiet fan cooling CSA approved to UL spec, CE compliant to low voltage and EMC directives Low housing temp – slightly above ambient
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.