Roche · Model CoaguChek XS Plus
Accurate, precise results in about one minute. The only system to perform onboard quality control and patient tests in a single test chamber. Results unaffected by heparin at therapeutic levels. INR corrected for hematocrit within specified range. Stores 2000 patient and 500 QC test results. Operator and QC lockout to ensure your policies are followed. Calibration via code chip. Stores lot data for up to 60 codes.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: INR does not match the clinical picture or a lab draw, on-board or liquid QC fails.
Root cause: Expired or heat-damaged strips, a wrong-technique sample (too small / too slow / air), or use outside the operating temperature range.
Symptoms: Numbered error (e.g. strip / temperature / timing errors) on the display, result suppressed.
Root cause: A specific condition indexed in the meter's error-code list - strip, sample, temperature, or a meter fault.
Symptoms: Meter does not recognise the test strip or the code chip.
Root cause: Contaminated strip-guide contacts, a wrong / missing code chip, or a damaged strip.
Symptoms: Short battery life, will not power on, will not charge (INRange).
Root cause: Depleted or aged battery.
Symptoms: Results will not download / sync via cable, Bluetooth or the base unit.
Root cause: Cable / port, Bluetooth pairing, or the docking base.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Store per the insert; heat damages them.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test strips and code chip Store per the insert; heat damages them. | Frequent wear item | $$ | Easy |
| Liquid QC controls | Frequent wear item | $$ | Easy |
| Battery / rechargeable pack | Frequent wear item | $ | Easy |
| Strip-guide / contact assembly | Periodic replacement | $$ | Moderate |
| Docking base / cable (XS Plus / INRange) | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Possible Misinterpretation of Displayed Measuring Units from INR to %Quick or Seconds; providing instructions to users for ensuring the meter is displaying INR results
Abnormally high INR test results with the affected CoaguChek test strips
Roche has confirmed the potential for an undetected elevated INR test result with the CoaguChek XS, CoaguChek XS Plus, and CoaguChek XS Pro meters. In rare cases, instead of a value, an ERROR 6 message is displayed.
The recommended cleaning procedures for the meter may cause a malfunction and falsely elevated test result reports.
The product was erroneously distributed to home users in contrast to its use for healthcare professionals only.
Erroneous Test Results: Monitor may display 'error' message or report falsely elevated patient results caused by insufficient amounts of active ingredient (thromboplastin) in the test strips.
If foil wrapped packages or other metallic objects are lodged behind the supply drawer, an electrical short may result and high heat generated; this could result in plastic melting and battery leakage for customers using 'C' cell batteries to power their base and could render the system inoperable (system won't turn on) for customers using the A/C adaptor without batteries.
Breaking the glass ampoule without first taking precautions may result in cuts/user injury from the glass.
Lack of assurance of sterility.
Erroneous patient results: may be falsely elevated or lowered, due to a packaging defect that allows air and moisture to enter the sealed pouch.
High frequency signals from other medical or communications equipment will result in a variable positive bias in test results.
Discrepancy between INR and the % Quick displayed on the meter.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.