Philips Healthcare · Model TruFlight Select
Time-of-Flight provides exceptional image quality Enhanced speed, productivity and throughput with the Extended Brilliance Workspace for Nuclear Medicine Enhances the patient experience The Philips patented OpenView gantry design enhances the patient experience, especially for claustrophobic and pediatric patients, and provides patient access for clinicians. Provides optimized workflow The TruFlight Select PET/CT offers streamlined operations including QC workflow, system startup and shutdown, and QC alignment. The Extended Brilliance Workspace for Nuclear Medicine (EBW NM) is an optional comprehensive portfolio of applications, providing PET, SPECT, and CT on the same platform for improved access, connectivity, filming, and reporting. State-of-the-art LYSO crystal and detector technologies Improves image quality, fast scans with the right choice of crystal and detector technologies Superb system sensitivity Offers excellent image performance for PET applications in oncology and cardiology High-definition PET reconstruction and image processing Optimizes image quality 4D ToF Allows for improved accuracy by managing patient motion 190 cm scan length for both PET and CT Provides true whole-body imaging for almost all patients in one scan 70 cm CT extended field of view Enhances oncology procedures
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →