Pedigo · Model P-2110
• All Pedigo fluid warmers are FDA approved. • UL & CSA approved. • 125 VAC. • Designed specifically for the warming of irrigation and intravenous fluids. (NOTE: Use of other types of fluids is not covered under our FDA approval). • Individual temperature controls for irrigation fluids and intravenous fluids allow for precise temperature settings for the proper type of fluid. • Irrigation temperature can be adjusted from 90 to 150 oF (32 to 66 oC) while the intravenous temperature range is 90 to 110 oF (32 to 43 oC). P-2145 low temp is 95oF. • The 4-digit LED display can be set to operate in Fahrenheit or Celsius. • Safety alarm warns if temperatures exceed 10 oF (6 oC) over the set-point temperature. • Built-in lock-out prevents inadvertent altering of temperature setting. • Glass window doors and interior lighting for easy visualization of contents. • Stainless steel construction with a full-perimeter stainless steel bumper. • 5" diameter, heavy-duty casters for ease of mobility, two with locking brakes. P-2110 has rubber feet for countertop use.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No heat, overheat alarm.
Root cause: Element or thermal fuse failure.
Symptoms: Setpoint error, alarm.
Root cause: Sensor aging.
Symptoms: Uneven warming, hotspot.
Root cause: Blower wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per patient.
Common R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Temperature probe Consumable per patient. | Periodic replacement | $ | Easy |
| Heating element / thermal fuse Common R&R. | Periodic replacement | $$$ | Moderate |
| Blower fan | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.