Olympus · Model GIF-2T160
• When used in combination with Olympus's dedicated flushing pump and the CV-180 or CV-160 video system center, an auxiliary water function is available to provide a clear view at the touch of a switch on the scope. • Dual channel design offers powerful suction capability and allows both channels to be used for Endo-Therapy accessories. • 3mm minimum depth of field for close-up observation. • 120° field of view and 4-way angulation (210° up, 90° down and 100° right/left) facilitate comprehensive examination of the upper digestive tract. • 12.6mm outer diameter insertion tube. • Compatible with laser probes for expanded treatment versatility. • Fully compatible with the CV-160, CV-140 and CV-100. • Scope ID™ function stores individual scope information and displays it on the monitor to facilitate endoscopy suite management.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →