Olympus · Model BF-XT160
• The BF-XT160 Videobronchoscope incorporates a large channel that measures 3.2mm across while still maintaining a narrow outer diameter of only 6.3mm - comparable to that of an equivalent fiberscope. • Powerful, versatile treatment and suction capability that expands the potential of video bronchoscopy. • Ergonomically designed control section and switch layout. • Fully insulated to minimize risk, this scope is compatible with electrocautery for added versatility. • The accessories are designed to the same specifications as those for Olympus’ previous and current bronchovideoscopes and bronchofiberscopes. This makes it easy to use the same accessory with different scopes, reducing equipment costs and simplifying accessory management. • Compatible with Olympus CV-160 and CV-180 Video Processors.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →