Olympus · Model BF-Q180
• The clear, crisp and high quality images produced redefine the standard of examination and treatment procedures in the bronchial tree. • Narrow Band Imaging™ technology enhances the observation of capillaries and the mucosal surfaces. NBI™ is only available from the Olympus EVIS EXERA II platform. • In addition to innovative and exceptional image quality, the slim design of this scope measures 5.1mm in diameter at the insertion tube and 5.5mm in diameter at the distal end. • 2.0mm diameter instrument channel can accommodate a full range of EndoTherapy accessories for the most efficient procedures possible. • Includes a standard set of EndoTherapy devices as well as disposable/autoclavable cleaning accessories. • The ScopeID™ function stores individual scope and patient information and displays it on the monitor to help facilitate smooth management in pulmonary labs and operating rooms. • Fully compatible with the Olympus CV-180, CV-160 and CV-140 video processors. • Compatible with laser treatment as well as Olympus electrosurgery devices.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →