Olympus · Model BF-MP160F
• With the CCD built into the control section, the BF-MP160F is able to have an insertion tube that’s as narrow as a fiberscope, yet at the same time is capable of delivering images that are much sharper and clearer than those of a fiberscope. • The image size on the monitor is significantly larger than that of a fiberscope, making images easier to observe. • There is no need to adjust focus and the automatic light adjustment system is fast and responsive, ensuring clear, high-quality images with minimum halation. • An advanced, ergonomic design makes the control section easier to handle and helps reduce operator fatigue. • With its ability to maneuver effectively in the peripheral bronchi, the BF-MP160F offers excellent instrumentation capability for transbronchial lung biopsy and cytology brushing under fluoroscopy. • At 2.0mm in diameter, the BF-MP160F’s inner channel is extremely large in proportion to its outer diameter and can accommodate a wide variety of EndoTherapy accessories. • The BF-MP160 is fully compatible with EVIS CV-100, CV-140, CV-160 and CV-180 Video Processors.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.