Olympus · Model BF-160
• Incorporates a compact, color-chip CCD (built into the scope tip) to provide clearer and more-detailed images than previous Olympus models • Larger image display size for easier viewing without sacrificing image quality • Narrow 5.3mm diameter distal • Length of the insertion tube has been increased from 550mm to 600mm to improve insertion and maneuverability of the scope • Bending section angulation range of 180º UP/130º DOWN allows easier handling and maneuverability in the smaller distal airways • Fully insulated to provide compatibility with electrosurgery and lasers • Ergonomically designed control section and switch layout helps reduce operator fatigue • Standard accessories are the same as those for all Olympus bronchoscopes
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.