NuAire · Model AllerGard NU-620R
DIRTY CAGE COLLECTION After the lab rat cage change process, a collection bin can be placed on the foldable shelf to collect dirty cages. The open bag from the sterile rat cages can be placed in the collection bin. As each animal is placed in a clean cage, the dirty cage can be stacked in the collection bin. After a stack of Innocage® IVC Rat Cages has been used; the technician can close the dirty bag and remove it from the collection bin for disposal. DEEP WELL FOR INNOCAGE® ICV RAT CAGES The work surface of the Animal Transfer Station Innovive® Rat Edition features a deep well in the clean segment of the work zone. The deep well allows a technician to place a sterile stack of Innocage® IVC Rat Caging and open the bag under HEPA-filtered air to begin the cage-changing process. IN WORKZONE FEED HOLDERS A package of Innocage® rat sterile feeders can be opened and stored in a holder under HEPA-filtered air, maximizing sterility. In addition, the in work zone holders allow a lab animal technician to access a feeder quickly, improving the cage-changing procedure. NU-620R WORK SURFACE The work surface features a pattern of air slots along the perimeter and across the interior of the work surface to segment the clean and dirty cage areas. At the same time, a left-side deep well allows for an easy-to-reach and space-saving area to place the stack of Innocage® IVC Rat Cages.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Occlusion alarm, no flow, upstream pressure high.
Root cause: Kinked set, clamped line, patient vein issue.
Symptoms: Air-in-line alarm, infusion paused.
Root cause: Air in set, improperly primed tubing.
Symptoms: Uncontrolled flow when door open.
Root cause: Worn roller or failed free-flow valve.
Symptoms: Stalled infusion, inaccurate rate.
Root cause: Peristaltic motor or encoder wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable; per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Air detector / ultrasonic sensor | Periodic replacement | $$ | Moderate |
| Door microswitch | Periodic replacement | $ | Fairly easy |
| Occlusion sensor assembly | Periodic replacement | $$ | Moderate |
| IV administration set Consumable; per patient. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →