NuAire · Model AllerGard NU-620R
DIRTY CAGE COLLECTION After the lab rat cage change process, a collection bin can be placed on the foldable shelf to collect dirty cages. The open bag from the sterile rat cages can be placed in the collection bin. As each animal is placed in a clean cage, the dirty cage can be stacked in the collection bin. After a stack of Innocage® IVC Rat Cages has been used; the technician can close the dirty bag and remove it from the collection bin for disposal. DEEP WELL FOR INNOCAGE® ICV RAT CAGES The work surface of the Animal Transfer Station Innovive® Rat Edition features a deep well in the clean segment of the work zone. The deep well allows a technician to place a sterile stack of Innocage® IVC Rat Caging and open the bag under HEPA-filtered air to begin the cage-changing process. IN WORKZONE FEED HOLDERS A package of Innocage® rat sterile feeders can be opened and stored in a holder under HEPA-filtered air, maximizing sterility. In addition, the in work zone holders allow a lab animal technician to access a feeder quickly, improving the cage-changing procedure. NU-620R WORK SURFACE The work surface features a pattern of air slots along the perimeter and across the interior of the work surface to segment the clean and dirty cage areas. At the same time, a left-side deep well allows for an easy-to-reach and space-saving area to place the stack of Innocage® IVC Rat Cages.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The infusion therapy is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.