NOA Medical · Model Platinum Stretcher
Powder coated steel frame and ABS base Back board is X-Ray translucent and is fitted with X-Ray cassette holder Foldable 5-Staff aluminum alloy guardrail Equipped with two USA hydraulic pumps Five functions: Adjustable back rest, leg rest, trendelenburg/reverse trendelenburg and height adjustment Telescoping IV stand 5th Wheel assist for directional control during transport 8 inch casters with central locking Two retractable push handles for controlled movement Mattress with moisture resistant cover
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Won't hold position, rolls when locked.
Root cause: Brake pad wear or linkage failure.
Symptoms: Hard to push straight, wobbles or drags.
Root cause: Bearing wear or a flat-spotted wheel.
Symptoms: Visible crack or looseness at a joint.
Root cause: Repeated load cycling.
Symptoms: Torn or cracked cover, exposed padding.
Root cause: Cleaning-chemical and UV degradation, routine wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace on visible wear or tear.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Upholstery / seat or surface cover Consumable - replace on visible wear or tear. | Periodic replacement | $ | Easy |
| Frame hardware (bolts, pins, bushings) | Major service part | $ | Fairly easy |
| Caster wheel assembly | Periodic replacement | $$ | Fairly easy |
| Brake / wheel-lock mechanism | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →