Monitor Instruments · Model MI-5000B
• Built in talk over with automatic pause while in use • 2 in 1 serial port configuration (pin-out compatible with older versions) • Excellent immunity to low line voltages • Rugged construction • Allows for field calibration of output levels • Three frequency threshold averaging on printouts • Capability for switching from automatic to manual as needed • Option to start either ear, and whether to test 8 kHz. • Starting ear, whether to test 8 kHz and other audiometer parameters can be stored in non-volatile memory • 'Listening' test controlled by the patient response switch from inside the booth • Optional automatic shut off after one hour when not in use (selection stored in non-volatile memory) • Elapsed test time printed on test results • Flags on printout show which thresholds were determined manually • Audible alert for end of test and error conditions (toggled active or inactive from front panel)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
| Patient electrode gel Consumable. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.