Moller-Wedel · Model MÖLLER 20-1000
The base of the floor stand houses a powerful 300 W xenon light source as well as a second identical but independed lamp module for backup. Quick exchange Filtered light against UV and IR radiation to protect the surgeon's eyes and the patient's tissue Control of light intensity via hand grip or foot switch Fluorescence For the operating system MÖLLER 20-1000 Möller-Wedel offers the equipment for fluorescence with ALA and ICG. Two light sources (one each for ALA and ICG) are integrated in the floor stand. SensoServo drive via SensoGrip Diaphragms against glare Switchable enhancer of the depth of field Bidirectional RS 232 interface for navigation Computer control of all motorized functions True overhead capability Slim floor stand design, hidden cables, stainless steel arms, easy to clean Options for diagnosis with ICG and ALA
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.