Additionally equipped with a 0° assistant scope, the MÖLLER Hi-R 900A is the perfect microscope for education and training. The assistant scope with integrated magnification changer (5-step) and focus enables relaxed working. Same 0° viewing and stereoscopic vision as the main observer Strong red reflex Easy swiveling between left and right side 160° inclinable eyepiece head Same ocular height as the main observer Coobservation and documentation Via a beam splitter, MÖLLER Hi-R 900 and MÖLLER Hi-R 900A can be equipped with adapters for video, still, and digital cameras, as well as with a stereoscopic observer scope. Via a sterile knob users may - even during operation - switch in a number of diaphragms and filters: Slit diaphragm, Daylight filter, Softlight filter, Blue filter (for fluorescence), and UV protection filter (yellow)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.