Moller-Wedel · Model EIBOS 2
The EIBOS 2 offers simultaneous observation of fundus and incision area, and it is safe for patient's eye by spring-loaded suspension. Its slim body allows space for handling instruments, and the fully centric mounting allows rotation depending on ergonomical aspects. It also has an internal focus ranging from the retina to the upper vitreous body, autoclavable mounting, adapter, and drape for prism body, b=and a swing-away position to minimize interference. For easy and secure exchange the lenses for the EIBOS 2 feature bayonet mounting. With the two available types macular as well as peripheral operations on the retina can be performed. Type 90 D: for approx. 90° viewing angle Type SPXL (132 D): for approx. 124° viewing angle The internal focusing is operated via a lever that can be mounted on the left and/or right hand side of the prism body. The traditional EIBOS lever is beneficial for surgeons that like to do the focusing him/herself. The round handle allows easy focusing for an assistant.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No or dim light, sudden loss during a procedure, colour shift, uneven field.
Root cause: Xenon or halogen lamp at end of life, a lamp-turret fault, or a fibre-optic cable break; the onboard spare lamp may not have switched in.
Symptoms: Microscope head drifts or will not hold position, worse after an accessory change.
Root cause: Arm not re-balanced after adding/removing a camera, tube or splitter, or worn magnetic / friction brakes.
Symptoms: Zoom, focus or the X-Y coupling will not run or is erratic from the foot control or handgrips.
Root cause: Drive motor, foot-control switch, handgrip, or cabling.
Symptoms: Hazy or low-contrast image, spots in the field.
Root cause: Dust or fingerprints on the objective protective glass or oculars, or condensation.
Symptoms: No or poor video output, will not white-balance, no capture.
Root cause: Camera module or video cable fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Let the lamp and mount cool before changing.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / halogen lamp Let the lamp and mount cool before changing. | Frequent wear item | $$ | Fairly easy |
| Fibre-optic light cable | Periodic replacement | $$ | Fairly easy |
| Swing-arm magnetic / friction brake & balance assembly | Major service part | $$$ | Difficult |
| Zoom / focus motor assembly | Major service part | $$$ | Difficult |
| Objective protective glass | Periodic replacement | $ | Easy |
| Mains fuse | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.