Molecular Devices · Model ImageXpress Confocal
High-intensity laser light source Capture images faster with shorter exposure times. Multiplex your experiments with 7 lasers and 8 imaging channels. Accurate 3D measurements Custom Module Editor 3D analysis is optimized for confocal imaging, enabling 3D measurements of volume and distance. Wide field of view Wide field of view enables whole-well confocal imaging and eliminates missed targets. Next-generation dual microlens enhanced spinning disk technology provides a large, flat field of view for more accurate and reproducible analysis. Exclusive AgileOptix™ spinning disk technology Provides increased sensitivity with specially designed optics, high-powered laser illumination, and sCMOS sensor. Swappable disk geometries provide flexibility between speed and resolution. IN Carta Image Analysis Software Leverages machine learning to improve the accuracy and robustness of high-content image analysis, delivering data insights that other technologies miss. Reduces the complexity of image analysis with intuitive guided workflows in a modern user interface. Multiple imaging modes The system offers phase contrast and brightfield label-free imaging, widefield and confocal fluorescent imaging with water immersion optics as a standard option. Automated water immersion objective technology Offers greater image resolution and sensitivity with up to 4x increase in signal leading to lower exposure times. Wide dynamic range Quantifies low and high intensity signals in a single image with >3 log dynamic range intensity detection.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The medical imaging is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio