Mindray · Model BeneVision N1
Compact, lightweight (2.0 lbs) 5.5″ capacitive touchscreen display with smartphone-like, multi-gesture control Innovative design eliminates difficult-to-clean seams and gaps Consistent intuitive user interface across N-Series platform Supports display of up to 6 waveforms Comprehensive standard measurements include 3, 5, 6-lead ECG, Masimo RD SET® SpO2, 2 IBP, NIBP, respiration, and 2 temperatures Arrhythmia analysis and atrial fibrillation (Afib) detection. Optional ST analysis and QT/QTc interval monitoring. Extensive data storage plus up to 48 hours of full disclosure Serves as the core parameter module for N-Series monitors Flexible transport solution with optional integrated or modular CO2 IP44 grade particle and water resistant 1.2 m drop test endurance Multiple mounting solutions including transport module rack with bedrail hooks Standard 2.4/5 GHz dual band wireless communication Defibrillator synchronization Battery run time of 8 hours (without integrated CO2)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →