Medtronic · Model 5391
Constant voltage output Basic pacing rate to 180 ppm Rapid atrial pacing at times 2 and times 4 of the basic rate up to 720 ppm Audible tone for sensitivity Easy set-up of pacing parameters by ergonomically designed dials Protective cover to safeguard against accidental changes to settings Long battery lifetime: up to 38 days of operation with a single 9 V Alkaline battery Audible warning tone for low battery, including low battery indicator Pacing run-away protection feature Patient cable system featuring patented connector with protected pins for convenient, reliable, electrical connections to increase patient safety Standard 1-year limited warranty
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Short charge-hold, low-battery on readiness test.
Root cause: Aged battery pack.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Won't charge or discharges unexpectedly.
Root cause: Relay/contactor wear.
Symptoms: Leakage alarm, self-test fail.
Root cause: Failed isolation components.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical - keep charged spares.
Expiration-dated consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient interface cable | Periodic replacement | $$ | Fairly easy |
| Rechargeable battery pack Critical - keep charged spares. | Periodic replacement | $$$ | Fairly easy |
| HV energy storage capacitor | Major service part | $$$$ | Expert-level |
| Defibrillation electrodes / pads Expiration-dated consumable. | Consumable | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →