Medical Illumination · Model CENTURA FULL VARIABLE SPOTLIGH
• Continuously adjustable spot from 3" (76mm) to 16" ( 406mm) diameter , providing homogenous light with 2,000 ft candles (21,500lux) at 36" (914mm) distance • Color temperature of 3,500º Kelvin • Easily replaceable 20 volt 150 watt halogen bulb with integral dichroic reflector • IR absorbing, color-correcting glass filter • Mechanical iris dimmer provides constant purity of light without affecting color temperature • 28" (711mm) articulating arm with integral compression spring • 23" Extension Arm • Arm rotates 40º up and down from horizontal plan • Lamphead and arm both rotate 540º • Standard sterilizable handle • Available with optional built-in fiber optic lightsource • Available in portable floor, wall, single or dual ceiling mounts, combination ceiling mounts with Centurion and ChuttleTrak ceiling track mounts.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.