MAQUET · Model HEATER-COOLER UNIT HCU 20
Independent temperature control of the patient and cardioplegia via separated water circuits Up to three external devices can be used simultaneously Fast and accurate temperature adjustment made possible by the split tank and automatically controlled mixing valve Reduced patient cooling times due to the exceptional cooling capacity of the highly effective ice-building system Silent operation – most surgeries can be performed without a running compressor Independent and precise flow control of the circuits allow the option of locating the unit outside the OR Minimized patient rewarming time due to the outstanding heating capacity and intelligent electronic management Gradient mode for physiologically optimized heating and cooling Proven patient safety and operating reliability ensured by the sophisticated electrical safety concept Simplified operation thanks to the user-friendly, flexible Control Unit with touch screen display Extremely short setup time required due to fast priming and automatic de-airing Polished stainless steel cabinet – easy to clean and damage resistant Easy to maneuvre using smooth running castor wheels with foot-lever operated brakes Hansen-quick couplings with icons facilitate fast and clear connection of oxygenator and cardioplegia heat exchangers Convenient and effective emptying of external devices.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Water temperature drifts from setpoint, patient temperature not tracking, over/under-temp alarm.
Root cause: Heater / thermoelectric or refrigeration fault, a temperature-probe fault, or a circulation-pump / flow fault.
Symptoms: Low-flow alarm, blanket not filling, pump noisy.
Root cause: Worn pump, an air-locked circuit, or a kinked / disconnected hose.
Symptoms: Patient temperature implausible or open-probe alarm, auto-control will not regulate.
Root cause: Damaged patient temperature probe or its connector.
Symptoms: Low-water alarm, water on the floor, air in the lines.
Root cause: Reservoir low, a hose / fitting leak, or a blanket leak.
Symptoms: Cannot cool water, compressor not running.
Root cause: Compressor, condenser fan, or a sealed-system fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Circulation pump | Periodic replacement | $$$ | Difficult |
| Patient temperature probe | Frequent wear item | $$ | Easy |
| Heater / thermoelectric module | Major service part | $$$ | Difficult |
| Hoses / quick-connectors | Periodic replacement | $$ | Easy |
| Refrigeration components (cooling units) | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.