Life-Tech · Model EZstim II
Versatile, pocket-size peripheral nerve stimulator. Automatically becomes either a full-function nerve locator or a neuromuscular block monitor, depending upon which patient lead wire is attached. Large, bright, easily read LCD continuously displays all instrument settings and status parameters. EShield protects against electromagnetic interference. Detachable lead sets allow quick and easy replacement of patient leads Function-specific lead wire sets guard against inappropriate use of stimulator. Large, high-sensitivity control knob facilitates precise current adjustment.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Ultrasound, e-stim, shortwave or laser channel delivers no or weak output, error on that channel, patient feels nothing.
Root cause: Applicator / electrode / handpiece fault, a lead / cable fault, dried electrodes, or an output-stage fault on that module.
Symptoms: Low or no ultrasound output, applicator-contact / BNR error, no warmth on a water-bath test.
Root cause: Worn or cracked applicator crystal, or a cable fault.
Symptoms: Intermittent stim, open-circuit error, uneven sensation.
Root cause: Worn lead wires or exhausted / dried self-adhesive electrodes.
Symptoms: Unresponsive or erratic touchscreen, parameters will not set.
Root cause: Touchscreen or controller fault.
Symptoms: Will not power on, short battery life, or shuts down on temperature.
Root cause: Power supply / fuse, an aged battery, or a cooling-fan fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Therapeutic-ultrasound applicator | Periodic replacement | $$ | Easy |
| Electrotherapy lead wires | Frequent wear item | $ | Easy |
| Self-adhesive / carbon electrodes | Consumable | $ | Easy |
| Output board / module | Major service part | $$$ | Difficult |
| Touchscreen / control assembly | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio