Leica Biosystems · Model ST5020 Multistainer
Safer Staining Process- Significantly reduce the potential for user errors as Leica Microsystem’s patented Code-Rack™ technology automatically identifies the desired stain protocol for individual racks and automatically starts the correct process. Simple Programming- Operational safety is enhanced by the Smart Graphical User Interface featuring intuitive software visualization with a color TFT touch-screen, multilingual software, and context-sensitive online help. Match your Laboratory's Needs- Enjoy flexibility with the multiple bath layout with 40 stations including up to 6 wash stations and up to 4 ovens/slide drying stations. Consistent Quality and Convenience- The Leica ST5020 reagent management system (RMS) helps to monitor reagent expiration, reagent rotation and stain quality. As a result: Reagent changes minimize disruptions to workflow and reduce delays. The RMS in conjunction with validated Surgipath reagents and protocols, ensures superior staining and coverslipping quality. Simple Programming- Operational safety is enhanced by the Smart Graphical User Interface featuring intuitive software visualization with a color TFT touch-screen, multilingual software, and context-sensitive online help.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.