Leica Biosystems · Model RM2235
Coarse-feed wheel: Coarse-feed wheel is 80 mm closer to the user compared to competitor products to support fatigue-free sectioning. Large 70mm vertical strokeThe large 70mm vertical stroke allows sectioning of super mega cassettes and also supports safer specimen changing due to the greater distance to the knife edge Adjustable handwheel system: Patented adjustable handwheel balance system protects the specimen because the object head does not drop into the knife when sectioning is stopped. Precision orientation systemThe optional 8° X/Y precision orientation system with calibrated controls helps to quickly orient already cut specimens (re-cuts). The system then rapidly returns the exact zero position, which is marked by two red indicators. Handwheel in any position: The handwheel brake on top of handwheel allows the handwheel to be locked in the upper position and the locking system below the handwheel allows it to be locked in any position.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →