Kendall · Model Genius 2
Tapered Probe Design Facilitates proper alignment with the ear canal. Tip Based Sensor Technology Improves accuracy and repeatability and minimizes the need for recalibration. Peak Select System Records & analyzes up to 100 measurements per scan. Rapid Response Time Easy to Use. Programmable Display Allows the thermometer to be customized according to hospital protocol. No-Touch Probe Cover Enhanced infection control. Real Time Temperature Accurate readings to improve clinical outcomes. F°/C° Toggle Button Customize temperature read outs to follow facility protocol. Pulse Timer Convenient for pulse and respiration monitoring. Extended Battery Life Takes 15,000 readings on 3 AA batteries. Easy Load Probe Covers (Thermometer) Ease of Use. Easy Load Probe Covers (Base) Quick and Easy Loading. ASTM and CEN Compliant Ensures accuracy and dependability. FAC System (Fast Ambient Change) Ensures accurate reading in fluctuating ambient temperatures.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The patient monitoring is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio