Kendall · Model Genius 2
• Tapered Probe Design Facilitates proper alignment with the ear canal • Tip Based Sensor Technology Improves accuracy and repeatability and minimizes the need for recalibration • Peak Select System Records & analyzes up to 100 measurements per scan • Rapid Response Time Easy to Use • Programmable Display Allows the thermometer to be customized according to hospital protocol • No-Touch Probe Cover Enhanced infection control • Real Time Temperature Accurate readings to improve clinical outcomes • F°/C° Toggle Button Customize temperature read outs to follow facility protocol • Pulse Timer Convenient for pulse and respiration monitoring • Extended Battery Life Takes 15,000 readings on 3 AA batteries • Easy Load Probe Covers (Thermometer) Ease of Use • Easy Load Probe Covers (Base) Quick and Easy Loading • ASTM and CEN Compliant Ensures accuracy and dependability • FAC System (Fast Ambient Change) Ensures accurate reading in fluctuating ambient temperatures
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →