Invendo Medical · Model invendoscope™ SC20
Gentle Highly flexible materials are being used to ensure a small bending diameter of the endoscope. In addition the electrohydraulic deflection mechanism of the endoscope tip obviates the need to use Bowden cables, and thus maintains the flexibility. The combination of these technologies ensures that the forces exerted by the endoscope are reduced. Hygienic Resource-intensive and critical cleaning processes of the endoscope are avoided as the invendoscope is designed for single-use only Easy-to-use All endoscope functions including forward and backward driving, deflection of endoscope tip, rinsing, suction, insufflation and recording of images are controlled via a simple handheld device. This makes performance of colonoscopies ergonomical and supports ease-of-use. Interventional Versatility Due to its 3.1mm working channel the invendoscope SC20 can be also used for biopsies and routine therapeutic procedures such as polypectomy. The centralized working channel with the support of the deflectable electrohydraulic tip allows access to all locations in the colon.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.