Electrohydraulic Lithotripsy System The most important factor in the success of ESWL treatment is focusing. The Compact and easily controllable structure of the system is important factor for focusing procedure. In Spark ESWL system, All procedures can be performed by a hand-held remote control. During lithotripsy, focus can be controlled from any desired location.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Low energy at the focal point, stones not breaking, long treatment times.
Root cause: Electromagnetic shock-head coil / membrane at end of life, degraded coupling (air or leak in the water cushion), or a HV generator fault.
Symptoms: Cannot target the stone, fluoroscopy or ultrasound localisation off, focal point misaligned.
Root cause: C-arm / X-ray source or image intensifier, the ultrasound localiser, or focal-point calibration drift.
Symptoms: Air in the cushion, leaks, poor patient coupling.
Root cause: Degassing unit, cushion membrane, or the fill / drain circuit.
Symptoms: No or erratic pulses, HV or charge alarm.
Root cause: HV supply, capacitor, or trigger circuit.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Pulse-count limited; focal-point recalibration required after replacement.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electromagnetic shock-head (coil / membrane) Pulse-count limited; focal-point recalibration required after replacement. | Periodic replacement | $$$$ | Expert-level |
| Coupling-cushion membrane | Frequent wear item | $$ | Moderate |
| Water degassing / conditioning unit | Periodic replacement | $$$ | Difficult |
| X-ray tube / image intensifier | Major service part | $$$$ | Expert-level |
| HV generator components (capacitor / trigger board) | Major service part | $$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.