Hettich · Model MIKRO 22 / 22 R
• Three complete running programs can be stored and recalled • Automatic lid locking, lid with see-through glass for speed control during centrifugation • Clearly arranged, water-protected foil keypad for entering the parameters • Stand-by mode (200R) maintains temperature / auto refrigeration shut-off after set time or when lid open • Brushless drive guarantees exceptionally smooth running and speed stability • Clearly arranged display: During centrifugation the actual values of the parameters are digitally displayed • Automatic rotor recognition • Speed (RPM): Input in increments of 10 • Relative Centrifugal Force (RCF): Input in increments of 10 • Temperature control in refrigerated models within a range of -20°C to +40C maintenance free frequency induction drive • Imbalance switch-off • Running time (t): Input in minutes and seconds • 2 year warranty
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.