HELMER · Model UltraCW
• Electronic flow meter for consistent, reproducible results • Programming flexibility for optimized results • Shorter wash cycles for faster results • Digital calibration for accurate saline volume • 24-place rotor option for increased capacity • Lower height profile on bench • Saline can be stored below cell washer Consistent Reproducible Results • Electronic flow meter provides precise saline fills versus flow timers • Digital calibration provides easy and accurate control of saline volumes while eliminating time-consuming and cumbersome manual calibration • Peristaltic pump allows saline supply to be located above or below the UltraCW Simple To Program • Convenient touchpad with easy to read digital LCD display provides process information, programming prompts, error messages, as well as time and wash status • Audible and visual end of process alerts Time Saving Performance • Increase productivity and turnaround times with faster wash cycles • Save 14 seconds/cycle, 1 minute/wash and 1 hour/60 washes Twice The Capacity With Optional 24-Place Rotor • Increase productivity by washing up to 24 tubes at once • Complete antibody identification with only one run Unique Rotor Design • Eliminates conventional plunger valve and associated bowl cleaning steps • Innovative design locks tubes in place while the rotor spins in the opposite direction for decant steps • Rotors accept either 10 x 75mm or 12 x 75mm standard tubes
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.