Hach Company · Model DR6000
The DR6000 has the most pre-programmed testing methods, including high-speed wavelength scanning across the UV and Visible Spectrum. A carousel sample changer allows up to seven sequential measurements. The Sipper Module, an instrument-controlled sample delivery system, increases precision by constant optical characteristics. The DR6000 comes with integrated QA software for scheduling, documenting and interpreting all of your needed quality measurements.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Blank or standard absorbance off, poor reproducibility, method verification fails.
Root cause: Lamp aging (xenon flash / tungsten / deuterium), contaminated cell compartment optics, or a scratched cuvette.
Symptoms: Low-energy or lamp warning, will not read.
Root cause: Lamp at end of life.
Symptoms: Instrument self-check or a verification standard fails.
Root cause: Wavelength-drive calibration or a filter / grating fault.
Symptoms: Barcode / RFID vial not read, wrong method applied.
Root cause: Cell reader or barcode window.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon flash / source lamp | Periodic replacement | $$ | Moderate |
| Cell compartment optics / lens | Major service part | $$ | Moderate |
| Cuvettes | Periodic replacement | $ | Easy |
| Cell / RFID reader | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.