GE HealthCare · Model Lunar iDXA
• Dual-energy Vertebral Assessment (DVA) - DVA aids in the diagnosis and assessment of vertebral deformations. DVA provides a rapid, dual-energy image of the AP and lateral spine, allowing clinicians to visually assess the presence of vertebral deformations. • Advanced Hip Assessment (AHA) - AHA includes all of the standard femoral regions of interest, plus additional key measurements including Hip Axis Length (HAL). • Multi-User Database (MUDB) - The Multi-User Database (MUDB) option allows multiple computer workstations to access DXA scan files simultaneously. Multiple Lunar bone densitometers can acquire and save images to a common database.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Failure to properly pre-indicate the technique factors to be used during a patient scan.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →