Fresenius · Model Stay Safe System
Fresenius Medical Care keeps a tradition of innovative renal care product development and sets the standard in peritoneal dialysis care. The stay·safe® system is an innovative PD connectology that makes training patients easy. The traditional clamping and unclamping steps are replaced with a simple dial. The patient just turns the dial through the 4 Step process. When the patient reaches Step 4, a PIN is inserted into the patient's extension set, closing the system prior to disconnect, thus eliminating the need for patients to mask and wash their hands.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Blood leak alarm, treatment stop.
Root cause: Optical cell dirty or true leak.
Symptoms: Conductivity out of range, dialysate alarm.
Root cause: Mixing valve or sensor fault.
Symptoms: Flow error, roller wear alarm.
Root cause: Pump segment fatigue.
Symptoms: UF inaccuracy, weight alarm.
Root cause: Balance system / scale fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Per-treatment consumable.
Single-use.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Blood pump roller | Periodic replacement | $$ | Fairly easy |
| Heparin pump syringe drive | Periodic replacement | $$ | Moderate |
| Blood tubing set / roller segment Per-treatment consumable. | Consumable | $$ | Easy |
| Dialyzer (filter) Single-use. | Consumable | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.