Ethicon · Model Ultracision Harmonic Scalpel
• Fast and easy setup and operation • On-screen diagnostics • Viewable from wide range of angles Universal Connector • Teardrop shape ensures proper alignment and limits potential damage to hand piece and device connector • Magnetized for ease of use and to ensure proper seating of connector • Automatic instrument recognition Compact Design • Takes up less space in the OR • Multiple placement options in the OR (cart, stand, or boom) • Allows for easy transportation between ORs Upgradeable Software • Designed to promote compatibility with future energy devices • Allows for future expansion to other products to limit the obsolescence of capital One generator for all HARMONIC® and ENSEAL® Devices • Powers current and future Ethicon Energy devices
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
An internal component may be cracked and become lodged behind the energy button potentially resulting in continuous activation of the device, may result in burns
The devices may have been assembled with an internal component that may cause continuous or inadvertent activation of the device.
Complaints of holes in Tyvek which can compromise the sterile barrier provided by the packaging.
Ethicon Endo-Surgery initiated a voluntary recall due to some lot numbers of the HARMONIC Hand Piece (HP054) and the HARMONIC Blue Hand Piece (HPBLUE), which impacts their compatibility with the HARMONIC Generator 300 (GEN04). The problem occurs after successful set up and initial use of HARMONIC Hand Pieces (HP054 and HPBLUE) with the Generator 300 (GEN04). The procedure is interrupted when