
Enova Illumination · Model XLT - 225A
Complete mobility in the OR with no tether to light source Illuminates even the deepest surgical cavity Adjustable illumination spot: 2” – 5” (5-15 cm) Co-axial alignment for maximum light penetration Up to 24” working distance 5+ hour battery life at full intensity 50,000 hours LED life Double padding for comfort.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Headlight out, dim, flickering, or colour shift.
Root cause: LED module / xenon lamp at end of life, a driver / power-supply fault, or a fibre-optic / light-cable fault.
Symptoms: Noticeably dim spot, dark speckle in the beam.
Root cause: Broken fibres in the light cable (common wear item).
Symptoms: Short run time, will not charge, cuts out.
Root cause: Aged battery pack.
Symptoms: Headband will not hold adjustment, spot will not focus, hinge loose.
Root cause: Worn headband ratchet or focus mechanism.
Symptoms: Source overheats or shuts down, loud fan.
Root cause: Failed or clogged cooling fan.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| LED module / xenon lamp | Frequent wear item | $$ | Fairly easy |
| Fibre-optic light cable | Frequent wear item | $$ | Easy |
| Battery / belt pack (portable) | Periodic replacement | $$ | Fairly easy |
| Driver / power supply | Major service part | $$ | Moderate |
| Headband ratchet / focus assembly | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio