DIAGNOSYS LLC · Model D315
E3 System; with Xenon ColorDome on an Operating Room Stand and 23" Monitor; 220V is a clinical and research visual electrophysiology system that functions by presenting a light stimulus to the eye, and then capturing, displaying, and storing the waveform of the electrical response from the retina (corneal electrode) or brain (occipital skin electrodes). Configuration: D315-1-2-CDXRL-23-N-N.
Intended use: An ophthalmic device used to record the changes in electric potential on or near the surface of the cornea to a reference distal point on the body, following stimulation of the retina by light, i.e., flashes of white light. The electroretinograph (ERG) recorder is used with a primary electrode [typically gold (Au), platinum (Pt) or silver (Ag)] and a reference electrode located almost anywhere on the body, e.g., cheek or ear lobe, and an amplifier that boosts the bioelectrical potential. Some are compatible with a personal computer (PC) for waveform storage and analysis. It is used in the diagnosis of retinal degeneration, night blindness, and circulatory disturbances of the retina.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Dim, uneven or no illumination; poor or hazy view; slit / filters not working.
Root cause: Bulb / LED at end of life, a power-supply fault, or contaminated optics.
Symptoms: Joystick or slide binds, will not hold position, chin-rest / head-rest drive faults.
Root cause: Worn stage bearings / slides or a positioning-drive fault.
Symptoms: Reading errors (tonometer / autorefractor / lensmeter), no or poor image capture (fundus / OCT), calibration fails.
Root cause: Sensor / camera fault, a calibration issue, or contaminated measurement optics.
Symptoms: No printout, images / data will not save or transfer.
Root cause: Built-in printer, the PC, or the network / EMR interface.
Symptoms: Instrument table or chin-rest will not raise / lower.
Root cause: Table / chin-rest actuator or its switch.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Illumination bulb / LED module | Frequent wear item | $$ | Fairly easy |
| Positioning-stage bearings / slides | Major service part | $$ | Moderate |
| Measurement sensor / camera module | Major service part | $$$ | Moderate |
| Built-in printer / paper | Periodic replacement | $ | Fairly easy |
| Chin-rest / table actuator | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.