DIAGNOSYS LLC · Model D315
E3 System; with Xenon ColorDome on an Operating Room Stand and 23" Monitor; 220V is a clinical and research visual electrophysiology system that functions by presenting a light stimulus to the eye, and then capturing, displaying, and storing the waveform of the electrical response from the retina (corneal electrode) or brain (occipital skin electrodes). Configuration: D315-1-2-CDXRL-23-N-N
Intended use: An ophthalmic device used to record the changes in electric potential on or near the surface of the cornea to a reference distal point on the body, following stimulation of the retina by light, i.e., flashes of white light. The electroretinograph (ERG) recorder is used with a primary electrode [typically gold (Au), platinum (Pt) or silver (Ag)] and a reference electrode located almost anywhere on the body, e.g., cheek or ear lobe, and an amplifier that boosts the bioelectrical potential. Some are compatible with a personal computer (PC) for waveform storage and analysis. It is used in the diagnosis of retinal degeneration, night blindness, and circulatory disturbances of the retina.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dim illumination, lamp error.
Root cause: Xenon/LED aging.
Symptoms: No phaco power, error.
Root cause: Tip or handpiece wear.
Symptoms: Unstable anterior chamber.
Root cause: Peristaltic pump wear.
Symptoms: Blurry/offset image.
Root cause: Camera calibration drift.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
High-value, track usage.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Illumination lamp / LED | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable. | Frequent wear item | $ | Easy |
| Imaging camera module | Periodic replacement | $$$ | Difficult |
| Phaco handpiece / tip High-value, track usage. | Periodic replacement | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.