Chattanooga · Model Triton DTS
5 unique DTS pull patterns deliver pull forces that closely mimic the hand-delivered feel clinicians provide, and add gradient, progressive range of motion and oscillations. Isolation of all phases of pull with independent timing for pretension, progression, traction and regression. Variable speed control for patient comfort and increased treatment flexibility. Pretension step eases guarding and provides greater comfort for the acute patient. SEMG initiated traction begins treatment when patient relaxes to the sEMG target Triton DTS TRT-600 Spine Therapy Table Features. Provides maximum patient comfort in prone and supine positions for both manual therapy and traction therapy. Pelvic Tilt section provides flexion of lumbar spine to improve positioning in traction and address pelvic asymmetry. Improved patient stabilization with removable axilla posts that prevent slippage during supine traction. Tilting (0°-35°) repositionable headpiece cradles the patient’s head comfortably, allowing flexion in prone or extension in supine positions.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Traction force not applied, CPM carriage will not move or stalls, drive assist weak, motion one direction only.
Root cause: Worn drive motor / leadscrew / actuator, a hand-control fault, or a control-board fault.
Symptoms: Set traction force or CPM angle not reached, load cell drifts, carriage overshoots or stalls short.
Root cause: Load-cell / position-sensor drift, a potentiometer fault, or a limit-switch fault.
Symptoms: Hand control unresponsive, the patient stop / reverse button does not work.
Root cause: Worn hand control or a damaged cable.
Symptoms: Rough or noisy travel, play in the carriage, frayed traction cord or rope.
Root cause: Worn bearings / slides or a frayed cable / cord.
Symptoms: Will not power on, short battery run time.
Root cause: Power supply / fuse or an aged battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive motor / leadscrew / actuator | Major service part | $$$ | Difficult |
| Load cell / position sensor / potentiometer | Major service part | $$ | Moderate |
| Hand control | Periodic replacement | $$ | Fairly easy |
| Bearings / slides / traction cord | Periodic replacement | $$ | Moderate |
| Power supply / fuse / battery | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.