CareFusion · Model Alaris Medley
The Medley System is intended for use in hospitals and healthcare facilities on adult, pediatric and neonatal patients. The Alaris PC Point-of-Care Unit is the core of the Alaris System, which provides a common user interface for programming the infusion and monitoring modules, helping to reduce complexity at the point of care.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The system alarms and displays an error message / code, therapy inhibited.
Root cause: A specific fault indexed in the Technical Service Manual troubleshooting chapter - a module, cable, connector, or board fault; use the maintenance software to diagnose.
Symptoms: Repeated occlusion or air-in-line alarms on a Pump module, delivery stops.
Root cause: Kinked or clamped line, an improperly loaded set, or a pressure / air-detector sensor fault.
Symptoms: A module (Pump, Syringe, SpO2, EtCO2) will not attach or the PC Unit does not see it.
Root cause: Worn IUI connector on the module or PC Unit, or a module fault.
Symptoms: Short run time on the PC Unit or a module, battery-fault alarm.
Root cause: Aged battery pack or a charging-circuit fault.
Symptoms: Delivered volume outside tolerance on the annual flow test.
Root cause: Worn pumping mechanism (Pump module) or drive (Syringe module).
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| PC Unit / module battery pack | Periodic replacement | $$ | Fairly easy |
| IUI connector assembly | Major service part | $$ | Moderate |
| Pump-module door / mechanism assembly | Major service part | $$$ | Difficult |
| Syringe-module drive / plunger grip | Major service part | $$$ | Difficult |
| IV administration / syringe set | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Under certain wireless network conditions a communication error can occur, which freezes the PC Unit screen, which may result in a delay of therapy. A delay of therapy may result in serious injury and/or death. CareFusion identified this potential risk associated with the Alaris PC unit model 8015 only (PC Unit) manufactured between December-2008 and September-2009.