Bio-Med Devices · Model 2003F
Blender for the Operating Room The 2003F blender was designed specifically for the operating room environment. It is a low flow blender that is configured with a 0-15 lpm flow meter installed. This allows a blended gas source to be delivered to a patient and minimizes the potential build-up of oxygen under the patient drape. The flow meter is attached to an integrated switch that allows the bleed flow (3 lpm) to only be active when the flow meter is in the upright position, and in use. This way, when the OR is not in use, the flow meter can be rotated forward and there is no waste of gas unnecessarily. The positioning of the flow meter in the OFF position can also be visualized without having to enter the room.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Delivered flow rate reads off from a known reference.
Root cause: Internal orifice or float-tube wear.
Symptoms: Won't hold set pressure, audible gas leak.
Root cause: Diaphragm or seal degradation.
Symptoms: Stuck, misreading, or broken gauge needle/dial.
Root cause: Mechanical gauge movement wear.
Symptoms: Gas leak at a hose or cylinder connection.
Root cause: Worn O-ring or damaged threads.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace on any detected leak.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Fitting / connector O-rings Consumable - replace on any detected leak. | Periodic replacement | $ | Easy |
| Regulator / valve seal kit | Periodic replacement | $$ | Fairly easy |
| Flow tube / orifice assembly | Periodic replacement | $$ | Fairly easy |
| Pressure gauge | Major service part | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →