
Aloka · Model ProSound F37
The most advanced broadband beam-forming technology combined with high speed image processing that allows for higher definition ultrasound imaging than ever before. Provides high quality imaging using an expanded range of harmonic signals. This technology results in excellent image resolution and sensitivity and improved penetration. Clearly displays differences in tissues, reducing speckle noise while maintaining the frame rate. It can also display outlines more clearly by selectively emphasizing boundaries. The ultrasound beam is transmitted and received in real time and in the multiple directions resulting in a reduction of speckle noise, suppression of artifacts, and improvement of contrast resolution allowing lesions to be clearly observed At the touch of a button the B-mode image is instantly optimized to the user’s preference. This technology continually monitors the user’s typical settings to optimally adjust the image when pressed resulting in less manual adjustments and more efficient examinations. The new high-efficiency probes are very lightweight and designed to be high in energy conversion to transmit high-quality ultrasound beams without raising the temperature on the probe surface. The image quality contributes to reduction of examination time Patient-friendly examinations enabled by the small size of the probe Basic measurement results can be transferred onto the report Unique probe holder for endocavity probes.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy or non-uniform image, missing sector, artefacts across multiple probes.
Root cause: Front-end / beamformer board fault, or a transducer-connector (probe port) fault.
Symptoms: A probe is not detected on one port but works on another.
Root cause: Worn probe-port connector or a scan-connector board fault.
Symptoms: Dead system, no boot, or intermittent shutdowns.
Root cause: Power supply / DC converter, the battery, or a system-board fault.
Symptoms: Short run time, will not charge, powers off unexpectedly.
Root cause: Aged battery pack.
Symptoms: Unresponsive controls, distorted or blank display.
Root cause: Touchscreen, control-panel board, or the display.
Symptoms: Thermal shutdown, loud fan.
Root cause: Failed fan or blocked air path.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Front-end / beamformer board | Major service part | $$$$ | Difficult |
| Probe-port / scan-connector board | Major service part | $$$ | Difficult |
| Power supply / DC converter | Major service part | $$$ | Difficult |
| Battery pack | Periodic replacement | $$ | Easy |
| Touchscreen / control-panel board | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio