Aloka · Model AOS 100NW
• Since the examination uses ultrasound, it does not need a special room and can also be used for young people and pregnant women. • Since the measurement takes only two minutes or less per patient, it causes less stress to the patient and is suitable for mass examinations. • There are a wide range of standard values for people, from children (9 years old) to 80-year-olds, to be assessed for bone conditions. • The dry procedure, which does not involve the use of water, is sanitary and easy to perform. • The system does not need a special room as would be required for radiological examinations; the installation is less costly and therefore economical. The measurements obtained by this method correlate with calcaneal and femoral bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA). • Medical payment is set for the use of diagnostic ultrasound (NHI point: 80).
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dropout, dead elements, image banding.
Root cause: Element delamination or cable damage from repeated use.
Symptoms: Intermittent image loss, connector-wiggle artifact.
Root cause: Repeated flexing and connector strain.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Dim image, color shift, dead pixels.
Root cause: Backlight or LCD panel aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Handle with care; most-replaced probe assembly.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Display panel | Major service part | $$ | Moderate |
| Ultrasound transducer / probe Handle with care; most-replaced probe assembly. | Periodic replacement | $$$$ | Moderate |
| Transducer cable assembly | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.