Agilent Technologies · Model 8697 Headspace Sampler
GC touch screen and browser interface shows headspace status, guides, and tracking Accommodates 48 vials on two removable racks or 120 vials on 5 removable racks (XL tray) Isolated carrier flow path as in the 7697A headspace sampler to safely vent your vials Improved transfer line with a captive septum retainer nut and improved inlet bracket for a more secure connection Optimized sample overlap lets you simultaneously heat and shake up to 12 vials Supports 10-mL, 20-mL, or 22-mL vials with no limitations on running mixed vial sizes Removable sample racks and smart park allow trays to be exchanged while the headspace sampler is operating so you can add samples as the sequence is running Optional cooling plate for the 8697-XL tray can chill sensitive samples to 4 °C Optional barcode reader for streamlined sample tracking Smart park button and tray rack LEDs show the status of the headspace sampler Transfer line interface (XLSI) accessory allows a headspace sampler and ALS to connect to the same inlet on the GC.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: "Vial leak detected" during pressurisation, sequence pauses or skips the vial.
Root cause: Poor vial crimp/seal, wrong cap, or a worn sampling-probe septum / seal.
Symptoms: System leak-check diagnostic fails, poor sensitivity or carryover.
Root cause: Loose transfer-line septum retainer nut, a bad ferrule, or a leak at the inlet bracket.
Symptoms: Gripper misses a vial or reports the wrong size, sequence action triggers.
Root cause: Tray or rack mis-seated, gripper misalignment, or a wrong vial size loaded.
Symptoms: Not-ready state, poor reproducibility, temperature fault.
Root cause: Oven heater, sample-loop heater, or a temperature-sensor fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Transfer line with septum retainer nut | Periodic replacement | $$$ | Difficult |
| Sampling probe / needle and seal | Periodic replacement | $$ | Moderate |
| Ferrule / seal kit | Frequent wear item | $ | Moderate |
| Vial gripper assembly | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.