
AGFA · Model DR 18M Mammo Panel
High DQE and low dose The scintillator of the detector uses directly deposited CsI. Combined with the high resolution pixel pitch of 76 µm, it delivers the excellent image quality required for digital mammography examinations. The high Detective Quantum Efficiency (DQE) and pixel size support lower radiation dose for patients. In addition, the lossless AED feature of the detector is, due to the simultaneously sensing of the X-ray, not increasing the patient dose. Cassette less workflow: faster and more efficient The DR 18M provides all the advantages of Direct Digital, while enabling you to maximize the use of your existing equipment. Part of Agfa’s DR Mammography solution, it includes the NX image acquisition workstation with MUSICA™ image processing.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Panel not detected, images not received, wireless / tethered link drops mid-exam.
Root cause: Detector battery (wireless), the Wi-Fi / tether cable, a docking / connector fault, or detector electronics.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead pixels / lines, calibration overdue or failing.
Root cause: Detector gain / offset calibration, a bad pixel map, or physical (drop) damage.
Symptoms: Short detector run time, will not charge in the cradle.
Root cause: Aged detector battery or a cradle / contact fault.
Symptoms: Cracked housing, tether cable intermittent.
Root cause: Drop or crush damage.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Detector battery (wireless) | Periodic replacement | $$ | Easy |
| Tether cable / access point | Periodic replacement | $$ | Fairly easy |
| Charging cradle | Periodic replacement | $$ | Easy |
| Flat-panel detector (exchange) | Major service part | $$$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
The firm received a complaint that when using the DX-D Mobile DR X-Ray unit they noticed the detector cable was hot.
The RF tags on the white protection sheets of the media stacks were incorrect.
Labeling problem
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio