ACUTUS MEDICAL, INC. · Model 800695
AcQMap to SmartAblate Generator Adapter.
Intended use: A small connector used to join the cable(s) from a handpiece/electrode(s) (active and/or return) to the generator of an electrosurgical system. This device will typically be used when the system components are from different manufacturers and the connections are not compatible. This is a reusable device.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy or missing catheter signals, ultrasound-derived chamber geometry incomplete, map fails.
Root cause: AcQMap catheter (ultrasound transducers / electrodes) contact or damage, a patient-cable / junction-box fault, or amplifier noise.
Symptoms: Catheter or surface-patch localisation drifts, geometry distorts.
Root cause: Surface reference patches poorly applied, or a localisation-field / patch-box fault.
Symptoms: Application hangs, map export fails, will not start a case.
Root cause: Workstation PC or software fault.
Symptoms: No map to the EP recording system or the lab displays.
Root cause: Video / network output fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable / junction box | Periodic replacement | $$$ | Easy |
| AcQMap catheter | Consumable | $$$ | Easy |
| Surface reference / localisation patches | Consumable | $ | Easy |
| Workstation PC | Major service part | $$$ | Moderate |
| Signal amplifier board | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio