ABBOTT DIABETES CARE INC · Model 70804
FreeStyle Lite Blood Glucose Monitoring System.
Intended use: A collection of devices including a portable, electrically-powered, semi-automated or automated instrument (self-testing meter), reagents, test strips and/or other associated materials and accessories (e.g., control solutions, lancets) intended to be used together for the quantitative measurement of multiple clinical chemistry analytes in a clinical specimen. Analytes detected may include electrolytes, specific proteins, clinical chemistry substrates (e.g., lipid profile), liver and/or cardiac function test analytes, and/or enzymes. It is intended to be used for self-testing by a layperson in the home, and some types may in addition be used at the point-of-care.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Result does not fit the clinical picture, poor agreement between duplicate strips, control solution out of range.
Root cause: Damaged, expired or wrong-lot strips, sample too small, or use outside the operating temperature range; haematocrit or interferents.
Symptoms: Error message on the display during or after a test.
Root cause: Faulty or mis-inserted strip, or a meter fault - repeat with a new strip.
Symptoms: Error stating the system is too hot or too cold.
Root cause: Meter and strips outside the specified operating range.
Symptoms: No display on strip insertion, meter will not start a test.
Root cause: Depleted battery or worn / contaminated strip-port contacts.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Single-use; observe the vial expiry and lot.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery | Frequent wear item | $ | Easy |
| Test strips Single-use; observe the vial expiry and lot. | Frequent wear item | $ | Easy |
| Control solution | Frequent wear item | $ | Easy |
| Strip-port contact assembly | Periodic replacement | $$ | Moderate |
| Lancing device | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Certain lots of FreeStyle and FreeStyle Lite Blood Glucose Test Strips produce erroneously low blood glucose results when using FreeStyle Blood Glucose Meters, FreeStyle Flash Blood Glucose Meters and the FreeStyle blood glucose meter built into the OmniPod system. Erroneously low results that are not recognized may pose significant risks to your health.
Product dispositioned for destruction was potentially diverted to end users.