Separate but together The monitor and PC are concurrent and independent. Quickly and easily access information from the hospital intranet or PC applications at the bedside with no compromise to patient vital signs monitoring or clinical alerts. Easy to use Fully compatible with the IntelliVue family of patient monitors, and with the same intuitive user interface, the MX800 can blend easily into your existing IT infrastructure, helping you to make the most of time, talent, and resources. More actionable information at the point of care Exceptional integration of monitoring and iPC computing capitalizes on next-generation “IT-centric” bedside applications, with a broad range of Clinical Decision Support tools for your team. The MX800 is highly configurable and widely scalable. Reduces the risk of infection The IntelliVue MX800 is designed with smooth surfaces and a minimum number of seams, and is easy to clean to reduce the risk of cross-contamination.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.