Abiomed, Inc. · Model Impella 2.5 MPC Pump Set
PUMP, BLOOD, CARDIOPULMONARY BYPASS, NON-ROLLER TYPE.
Intended use: A sterile tubular device with a built-in electrically-powered axial flow pump (e.g., a micro motor with an impeller) at the distal end, designed to provide circulatory assistance to the heart by pumping blood during heart failure. It is inserted through the lumen of the aorta and into the left ventricle, surgically or percutaneously via an artery, and connected to an external control unit; it moves blood from the left ventricle to the aorta across the aortic valve. It is typically used emergently post acute myocardial infarction (AMI), electively for high-risk cardiac catheterization, for open chest surgery, and during transport between hospitals. This is a single-use device.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Flow drops below the set level, flow alarms, haemodynamic support falling.
Root cause: Pump position shifted (too far in / out or across the valve), suction from low LV volume, a kinked catheter, or a motor / rotor fault.
Symptoms: Purge pressure high or low, purge-flow alarm, purge cassette fault.
Root cause: Purge cassette / tubing occlusion or air, wrong purge-fluid concentration, or a purge-pump fault in the controller.
Symptoms: Damped or absent placement (aortic) pressure waveform, "Impella position unknown".
Root cause: Optical / pressure sensor in the catheter, air in the pressure lumen, or a catheter-connector fault.
Symptoms: Automated Impella Controller alarms, will not run on battery, screen or interface fault.
Root cause: Controller hardware fault or an aged controller battery.
Symptoms: Intermittent motor current or signal, connection alarms.
Root cause: Worn catheter connector or the controller connector cable.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Single-use consumable.
Single-use; the pump/rotor is part of the catheter.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Automated Impella Controller (AIC) battery | Periodic replacement | $$$ | Fairly easy |
| Purge cassette / tubing set Single-use consumable. | Consumable | $$ | Easy |
| Connector / mobile-cable assembly | Periodic replacement | $$$ | Easy |
| Impella catheter / pump set Single-use; the pump/rotor is part of the catheter. | Consumable | $$$$ | Easy |
| AIC console (loaner / exchange) | Major service part | $$$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Potential for thrombus formation during prolonged use of the introducer.
Exposure to the low purge pressure occurrence may result in persistent low purge pressure alarms and, in some cases, interruption or loss of mechanical circulatory support.
Increased risk of purge leaks with Generation 1 purge cassettes.
Differential pressure (dP) sensor in Impella RP devices may malfunction, causing sensor values to drift.
Device packaged in incorrect outer box carton.
Optical Sensors have been damaged due to physical interaction between the inlet and another device resulting in a Placement Signal Not Reliable (PSNR) alarm and loss of Central Venous (CV) Placement Signal, Pulmonary Artery (PA) Placement Signal & Pulmonary Artery Pulse Index (PAPi) metrics. Abiomed is reinforcing that there is a risk of potential interaction between the tip of guidewires, indwelling central venous lines or devices and inlet of the Impella pumps listed above during the insertion, manipulation, and removal of those devices. The interaction may result in optical sensor damage, temporary pump stop, or permanent pump stop.
A potential device interaction between the Shockwave Coronary IVL Catheter and left-sided Impella Pumps during coronary interventions. Currently there is no Abiomed labeling (IFU etc.) content related to this potential interaction, so Abiomed will update the IFU to include information on this potential device interaction.
Nine (9) Impella CP pumps failed inspection and were inadvertently released.
IFU has been updated to include warnings about the risk of the inlet perforating through the myocardial wall of the left ventricle due to operator handling.
New warnings are being added to the Instructions for Use for all affected products to reduce the possibility of fibers being drawn into the Impella, which may result in low flow of the device.
The following features have been disabled from the web-based portal because the FDA has not evaluated these features for safety and effectiveness: Notifications via email feature; AIC alarm color on case tile feature; Sort case tiles by AIC alarm color feature; Pump metric display on case tile feature
Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into the vasculature and/or access site, leading to an infectious process, bacteremia or sepsis
A higher than expected rate of thrombus formation or deposition has been observed. The risk is for thrombus formations or deposits on indwelling central venous lines or cannulas may break free and enter into the Impella RP Flex, resulting in reduced flow, loss of support, or hemolysis
There is a potential risk for unintentional interaction of the Impella motor housing with the distal stent of a transcatheter aortic valve replacement (TAVR) resulting in destruction of the impeller blades. This has resulted in low flow from the damaged Impella system. Systemic embolization of the fractured impeller material is a possibility.
The Impella 5.5 pump experienced a heightened complaint rate for purge leaks.
Pump may separate at the motor housing while device is explanted